LATEST UPDATESEnglish
VVUUKU NewsA curated stream of attributed news links
Stay close to the storiesA clear view of source-attributed news headlines.
Science

Ultrasound Diaphragm Measurements Fail to Track Overall Body Muscle Mass

Bedside ultrasound measurements of the diaphragm do not serve as a dependable surrogate marker for systemic skeletal muscle mass in individuals without pulmonary disease, according to a cross-sectional pilot study conducted by clinical researchers at Spaulding

Illustrative imageIllustrative image

Bedside ultrasound measurements of the diaphragm do not serve as a dependable surrogate marker for systemic skeletal muscle mass in individuals without pulmonary disease, according to a cross-sectional pilot study conducted by clinical researchers at Spaulding Rehabilitation Hospital and published in Clinical Nutrition Open Science. Evaluating whether sonographic assessments of the primary inspiratory muscle could mirror established nutritional anthropometrics, the investigators evaluated fifty-one healthy adult volunteers using seven distinct diaphragm thickness and thickening fraction parameters. Across both unadjusted and multivariable general linear regression models, none of the seven ultrasound metrics demonstrated a statistically significant association with calf circumference. Furthermore, while the diaphragm thickening fraction during deep inspiration exhibited a statistically significant association with fat-free mass index derived from bioelectrical impedance analysis after adjusting for demographic and clinical covariates, the observed effect size was exceptionally small, demonstrating that the relationship lacks clinical relevance. These findings suggest that regional diaphragm musculature operates largely independently of peripheral and whole-body muscle reserves in adults free from underlying respiratory disorders.

Assessing loss of skeletal muscle mass remains one of the primary phenotypic criteria for diagnosing malnutrition and sarcopenia among hospitalized adult patients. The Global Leadership Initiative on Malnutrition has established consensus frameworks emphasizing muscle assessment, yet implementation across international clinical environments remains hampered by unequal access to specialized body composition technologies and varying operator training. While nutrition-focused physical examinations remain widespread in routine bedside care, they depend heavily on subjective visual and tactile impressions. In response, medical ultrasound has steadily gained clinical adoption as an objective, non-invasive imaging modality capable of capturing direct anatomic dimensions of muscle thickness and tissue architecture. Because ultrasonography operates free of ionizing radiation, requires relatively portable equipment, and permits serial bedside repetitions, clinicians have sought to establish whether scanning the diaphragm could offer a rapid, reliable proxy for whole-body muscularity without the operational hurdles of full-body scans.

From an anatomical and physiological perspective, the diaphragm serves as the essential motor engine of life-sustaining ventilation, separating the thoracic and abdominal cavities and remaining active throughout the entire lifespan. Prior investigations highlighted that the diaphragm can reflect systemic muscle atrophy while potentially showing resistance to age-related degeneration, sex disparities, and fluctuations in overall body mass index. However, past clinical studies investigating links between diaphragm thickness and conventional muscularity markers—such as calf circumference, total fat-free mass, appendicular skeletal muscle mass relative to body mass index, and skeletal muscle index—yielded contradictory conclusions. A substantial portion of the existing scientific literature focused almost exclusively on critically ill patients receiving invasive mechanical ventilation or individuals suffering from severe chronic respiratory conditions, such as chronic obstructive pulmonary disease. Because pulmonary disorders induce structural hyperinflation and pathological alterations in respiratory mechanics, the baseline behavior of the diaphragm in healthy human physiology remained poorly delineated.

To rigorously evaluate diaphragm behavior, researchers must account for the continuous dynamic variations that occur across the respiratory cycle. As air moves into and out of the lungs, muscle thickness changes measurably during each distinct ventilatory phase, encompassing resting tidal volume, functional residual capacity, total lung capacity, and residual volume. To capture these mechanics, the research team cataloged seven specific diaphragm parameters, dividing them into four direct anatomical thickness measurements and three calculated functional indices known as thickening fractions. The direct measures comprised diaphragm thickness at the end of quiet inspiration during tidal breathing, thickness at the end of quiet expiration at functional residual capacity, thickness at the end of deep inspiration at total lung capacity, and thickness at the end of deep expiration at residual volume. Because baseline anatomical thickness varies naturally across individuals, thickening fractions calculate the percentage change between expiration and inspiration. These dynamic indices included the deep thickening fraction, the quiet thickening fraction, and a mixed thickening fraction combining total lung capacity and functional residual capacity.

Conducted in Boston, Massachusetts between March and July 2026, the investigation recruited adult employee volunteers who provided electronic informed consent through secure institutional data capture platforms under institutional review board oversight from Mass General Brigham and Rutgers University. To eliminate confounding mechanical distortions, the protocol enforced strict exclusion criteria targeting any condition that alters diaphragm positioning or diaphragmatic excursion. Individuals were excluded if they presented with chronic obstructive pulmonary disease, cystic fibrosis, prior lung transplantation, prolonged mechanical ventilation within the preceding three months, neuromuscular disorders, phrenic nerve trauma, congestive heart failure, severe ribcage structural abnormalities, or scoliosis. Furthermore, the protocol excluded pregnant women and participants presenting with active fluid retention, ascites, recent systemic sepsis, or cardiac implantable electronic devices that could interfere with bioelectrical impedance analysis. The resulting cohort comprised fifty-one ambulatory adults aged nineteen to sixty-three years who demonstrated comfort in executing precise voluntary breathing commands.

Sonographic data collection adhered strictly to standardized international consensus recommendations established by the SARCopenia through UltraSound working group. Participants rested supine with the head of the examination bed elevated thirty degrees to minimize positional restriction of diaphragmatic excursion and reduce variability across serial evaluations. The primary investigator completed extensive pre-study technical training under a board-certified pulmonologist and reviewed procedural validity with specialized sonographers. Imaging was executed using B-mode ultrasound equipped with a high-frequency linear transducer held against the right chest wall within the zone of apposition, situated between the eighth and tenth intercostal spaces along the anterior and mid-axillary lines. When acoustic shadowing from lung tissue obscured deep inspiratory views in the sagittal plane, the probe was shifted to a transverse orientation. Participants signaled maximal breath-holding at the terminal point of each ventilatory phase by raising their left thumb, allowing the sonographer to freeze the image and place electronic calipers at the midpoint between the pleural and peritoneal membranes to calculate arithmetic means from three replicate captures.

Alongside sonographic imaging, the investigators obtained two validated clinical indicators of systemic muscularity: calf circumference and bioelectrical impedance analysis. Calf circumference was recorded to the nearest millimeter using an inelastic measuring tape placed across the widest prominence of the right gastrocnemius muscle while participants maintained a seated posture with ninety-degree knee and ankle flexion, with values adjusted for sex and body mass index according to standard nutritional formulas. Fat-free mass index was quantified following a minimum four-hour fast using a multi-frequency bioimpedance analyzer with four electrodes arrayed across the right wrist and ankle. Reflecting the total non-fat tissue mass standardized against height squared, fat-free mass index served as an accepted body composition benchmark endorsed by international malnutrition guidelines. Preliminary evaluations demonstrated that calf circumference and fat-free mass index shared no collinearity or co-dependence within this healthy cohort, justifying independent linear modeling for each dependent variable.

The statistical analysis plan employed general linear models to test both unadjusted and multivariable associations, controlling for age, sex, body mass index, and categorical race and ethnicity. To safeguard biological plausibility, the investigators identified and excluded data instances that generated negative thickening fractions, an impossible physiological state that reflects participant breath-holding errors or incomplete ventilatory phases during testing. In total, seven participants had their tidal volume, functional residual capacity, quiet thickening fraction, and mixed thickening fraction parameters omitted from specific modeling steps due to these ventilatory inconsistencies. Bivariate correlation analyses further evaluated collinearity among the ultrasound parameters, establishing that direct thickness at tidal volume, thickness at total lung capacity, deep thickening fraction, and quiet thickening fraction remained statistically distinct from one another, enabling their combined inclusion within fully adjusted multivariable models.

Descriptive evaluation of the fifty-one enrolled volunteers revealed a mean age of 37.63 years, with female participants constituting 68.6 percent of the sample. Within the cohort, 21.6 percent presented with a healthy body mass index, 49.0 percent fell within overweight classifications, and 29.4 percent met criteria for clinical obesity. Across all four direct thickness parameters, intra-rater measurement reliability proved exceptionally high, with single-measure intraclass correlation coefficients ranging from 0.948 to 0.971, median coefficients of variation between 3.45 and 4.03 percent, and standard errors of measurement below 0.27 millimeters. Direct thickness peaked predictably during deep inspiration at total lung capacity, yielding a mean of 4.22 millimeters, followed by quiet tidal inspiration at 2.14 millimeters, functional residual capacity at a median of 1.77 millimeters, and residual volume at a median of 1.73 millimeters. Thickening fractions followed identical ventilatory gradients, with the deep thickening fraction averaging 133.50 percent, compared to a median of 11.75 percent for quiet tidal breathing.

Regression modeling revealed a striking absence of diagnostic alignment between the ultrasound parameters and peripheral anthropometrics. None of the seven ultrasound metrics showed a statistically meaningful association with calf circumference across either unadjusted evaluations or adjusted models accounting for age, sex, body mass index, and race and ethnicity. When examining fat-free mass index, direct diaphragm thickness at total lung capacity initially demonstrated a significant positive relationship in unadjusted analysis, displaying an unstandardized regression coefficient of 0.537 and a p-value of 0.032. However, this statistical significance evaporated completely once the model controlled for standard demographic and anthropometric covariates. In the fully adjusted multivariable model, only the deep thickening fraction retained an independent, statistically significant association with fat-free mass index, producing an unstandardized coefficient of 0.008 with a p-value of 0.015 and explaining 88.7 percent of model variance in combination with clinical covariates.

Despite achieving formal statistical significance, the clinical utility of the deep thickening fraction proved negligible upon examining the magnitude of its biological effect size. The regression coefficient of 0.008 indicated that an absolute one percent increase in diaphragm thickening fraction during deep inspiration corresponded to an increase in fat-free mass index of only 0.008 kilograms per square meter. In practical terms, an individual would need to demonstrate an enormous, physiologically unrealistic change in diaphragm thickening capacity to observe even a minor shift in systemic muscle index. Exploratory subgroup evaluations indicated that sex significantly modified the relationship between functional residual capacity thickness and calf circumference, with males exhibiting a stronger correlation than females. Similarly, race and ethnicity demonstrated interaction effects with functional residual capacity thickness. However, sensitivity analyses excluding identified statistical outliers confirmed that these minor subgroup deviations did not alter the central finding of negligible clinical association.

Reflecting on the barriers and methodological challenges encountered during the investigation, the authors underscored that the study’s central outcome remains an essentially null result that should temper enthusiasm for adopting diaphragm ultrasound as a quick surrogate for whole-body muscularity. Several technical limitations warrant careful consideration in clinical practice. The reliance on participant self-judgment during unassisted breath-holding, rather than confirmation via objective laboratory spirometry, introduced operator and participant measurement biases that explained the occurrence of biologically implausible negative thickening fractions. Furthermore, although bioelectrical impedance analysis and calf circumference represent accessible clinical tools, they remain less precise than dual-energy x-ray absorptiometry for isolating appendicular skeletal muscle mass, particularly in study cohorts exhibiting a high prevalence of overweight and obesity. The authors concluded that while serial diaphragm sonography remains highly reproducible and technically feasible for monitoring local respiratory mechanics, bedside clinicians cannot rely on diaphragm ultrasound parameters as indicative surrogates for whole-body nutritional status or systemic muscle depletion.

Subject of Research: Diagnostic utility of ultrasound-measured diaphragm thickness as a proxy for systemic skeletal muscle mass

Article Title: Ultrasound-Measured Diaphragm Thickness and Its Relationship with Calf Circumference and Fat-Free Mass Index: A Cross-Sectional Study in Patients Without Pulmonary Disease

Article References: Cerella, L., Divo, M. J., Samavat, H., Nanni, G., Hawes, C., Rigassio Radler, D., & Byham-Gray, L. (2026). Ultrasound-measured diaphragm thickness and its relationship with calf circumference and fat-free mass index: A cross-sectional study in patients without pulmonary disease. Clinical Nutrition Open Science, 70, Article 100765. https://doi.org/10.1016/j.nutos.2026.100765

Image Credits: AI Generated

DOI: 10.1016/j.nutos.2026.100765

Keywords: diaphragm ultrasound, muscle mass assessment, fat-free mass index, calf circumference, bioelectrical impedance analysis, malnutrition screening, clinical nutrition, thickening fraction, cross-sectional study, skeletal muscle index, ultrasonography, zone of apposition, body composition, respiratory mechanics, bedside imaging, intra-rater reliability

News Source: Ophelia Keating. (November 23, 2026). Ultrasound Diaphragm Measurements Fail to Track Overall Body Muscle Mass. Scienmag.